Calibration of Structured Light Scanning System

Publications

Share / Export Citation / Email / Print / Text size:

International Journal of Advanced Network, Monitoring and Controls

Xi'an Technological University

Subject: Computer Science, Software Engineering

GET ALERTS

eISSN: 2470-8038

DESCRIPTION

0
Reader(s)
0
Visit(s)

Comment(s)
0
Share(s)

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue / page

Related articles

VOLUME 6 , ISSUE 2 (Jul 2021) > List of articles

Calibration of Structured Light Scanning System

Yi Guo * / Xiaoyi Ruan *

Keywords : Camera Calibration, Point Cloud Stitching, Dental Model, Three-Dimensional Measurement

Citation Information : International Journal of Advanced Network, Monitoring and Controls. Volume 6, Issue 2, Pages 56-64, DOI: https://doi.org/10.21307/ijanmc-2021-017

License : (CC-BY-NC-ND 4.0)

Published Online: 12-July-2021

ARTICLE

ABSTRACT

Graphical ABSTRACT

Content not available Share

FIGURES & TABLES

Figure 1.

The measurement system

Figure 2.

Schematic diagram of camera imaging

Figure 3.

Principle of camera imaging

Figure 4.

Camera distortion

Figure 5.

Rasterization of the checkerboard calibration board

Figure 6.

Design drawing of calibration board

Figure 7.

The calibration process based on circular marking points

Figure 8.

Main view of calibration board

Figure 9.

Position relationship diagram between points and straight lines

Figure 10.

Automatic matching of marking points at different angles

REFERENCES

  1. Gerd H. Phydical linits of 3D-sensing [J]. SP IE. 1992.
  2. Patzelt SBM, Emmanouilidi A. Accuracy of full-arch scans using intraoral scanners. Clin oral investig [J], 2014.
  3. Kachalia P R, Geissberger M J. Dentistry a la carte: in-office CAD/CAM technology [J]. Journal of the California Dental Association, 2010.
  4. Zhongyou Zhang. A flexible new technique for camera calibration [J]. Technical Report MSRTR-98-71, Microsoft Research, 1998.
  5. Miyazaki T, Nakamura T. Current status of zirconia restoration [J]. prosthodontres, 2013.
  6. I. S. Jacobs and C. P. Bean, “Fine particles, thin films and exchange anisotropy,” in Magnetism, vol. III, G. T. Rado and H. Suhl, Eds. New York: Academic, 1963, pp. 271–350.
  7. Van Noort R. The future of dental devices is digital[J]. Dental materials, 2012.
  8. Kachalia P R, Geissberger M J. Dentistry a la carte: in-office CAD/CAM technology [J]. Journal of the California Dental Association, 2010.
  9. Rechard A. Newcombe. Kinect Fusion:Real-Time Dense Surface Mapping and Tracking [J]. IEEE International Symposium on Mixed and Augmented Reality 2011 Science and Technolgy Proceedings, 2011
  10. Patzelt SBM, Emmanouilidi A. Accuracy of full-arch scans using intraoral scanners. Clin oral investig [J], 2014.

EXTRA FILES